Headquarters (208) 286-7772
Headquarters (208) 286-7772
Thank you for building within the Middleton Rural Fire District and Star Fire Protection District. We look forward to working with you during the construction process.
SUBMITTING APPLICATION AND PLANS FOR REVIEW:
GENERAL REQUIREMENTS FOR SINGLE-FAMILY RESIDENTIAL CONSTRUCTION:
WATER SUPPLY (Fire Flow):
If the residential structure is more than 1000 ft. from a certified hydrant, a water supply is required.
One and two-family dwellings not exceeding 3,600 square feet require a fire-flow of 1,000 gallons per minute for a duration of 1 hours to service the entire project.
One and two-family dwellings in excess of 3,600 square feet require a minimum fire flow as specified in Appendix B of the 2018 International Fire Code.
The fire-flow calculation area shall be the total floor area of all floor levels within the exterior walls and under the horizontal projections of the roof of a building.
APPARATUS ACCESS:
Fire apparatus access roads shall have an unobstructed width of not less than 20 feet, exclusive of shoulders, with an unobstructed vertical clearance of not less than 13 feet 6 inches. The drivable surface shall be capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Access roads over 150 ft. from the public roadway will require a turn-around.
APPARATUS ACCESS WIDTHS:
Length Width Turn-around Required
0-100 ft. 20 None required
151-500 ft. 20 Required
501-750 ft. 26 Required
Over 750 ft. Special approval required
Effective May 1, 2020, we will now be accepting electronic plans for review.
HOME KNOXBOX PROGRAM:
The Middleton and Star Fire District offer a Home Knoxbox program for single-family residential structures. Knoxbox will help first responders gain access in the event of an emergency. For more information, contact the Fire Code Official.
INSPECTIONS:
Inspections are to be scheduled in a timely manner by the Builder or Project Manager. To schedule an inspection contact (208) 585-6650 and provide the following information:
1) Fire District Permit Number
2) Inspection needed
3) Address
4) Contact information
Please allow 48 hours for inspections.
Fire Code: 2018 International Fire Code.
Fire Code Offical
Victor Islas
Office: (208) 286-7772
Email: permits@midstarfire.org
Format accepted: PDF Only
Copyright © 2023 Middleton Star Fire Districts - All Rights Reserved.
Powered by GoDaddy Website Builder